Ai Mosheng precision air conditioning cooling ATP05C1\ATC05N1 one year warranty room for air conditioning 5.7KW

price:USD$12600.00
discount 70% in 2018-09-23 to 2018-09-25
price: USD$ 8820.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Description:
LiebertATP05 small computer room dedicated air conditioning is Emerson network energy Co., Ltd. for the application of non humidification needs of the development of the room for air conditioning products. With single-phase power supply chanlengxing and single-phase power supply with heating type two models.
 
Application range:
The following scenarios for non humidification requirements
- small computer room
- small communication room
In the substation, substation
In the distribution network,
- small equipment
- Communication Station
In all kinds of outdoor room
 
Applicable industry:
- Education
- Financial
- traffic
- communication operators
- power
- Medical
- government agencies
- Enterprise
 
Characteristic
 
High reliability:
Design of refrigeration system - efficient energy saving operation, energy consumption than ordinary comfort air conditioning saving 20-30%;
In the large volume small enthalpy design, meet the needs of professional computer room;
- follow the 365 days a year, 24 hours a day running long life design; each one of the products through strict factory test
 
Excellent human-computer interaction interface:
Full - Chinese large screen LCD backlight display, user-friendly interface and easy operation, precise microcomputer control system;
Multi - password protection to prevent misoperation;
- operation state display, intelligent fault diagnosis functions;
Intelligent control technology - advanced, record the running time of each main parts;
- set the parameters of automatic protection, even after the power outage can also save the operation parameters and alarm record;
Can store 200 historical alarm information
 
Strong adaptability of power grid:
Ultra - wide input voltage design, allowable voltage fluctuation range of 220V + 15%;
- have low voltage automatic detection and protection function is unique, self starting function calls;
- set start delay function, to avoid the call flash effect the stability of the equipment, or because of multiple devices at the same time to boot front-end power switch "trip caused by the surge"
 
Easy operation and maintenance structure:
- all positive maintenance structure, convenient maintenance and easy installation unit, flexible unit
 
Super network management function:
- standard RS485 monitoring interface, and provide free communication protocol, system monitoring and management software with DW-PSMS computer room, centralized control room of power equipment, environment and alarm management;
- with switch flexible function, realize the automatic switching unit, rotation function;
In the remote switch machine, remote alarm, alarm query, remote troubleshooting and other management functions;
- compatible with Emerson RDU series RDU-Cooling air conditioner includes monitoring: monitoring software, RDU-Sic RDU-A version, and RDU-M;
Model of indoor unit
ATP05C1
Cold capacity (W)
Refrigerating capacity
5700
Sensible cooling capacity
5130
Power supply system
Single phase, 220V/1P/50Hz
Fan
Standard air volume (m3/h)
1300
Number of fans
1
Compressor
Number
1
Electric heating
Power (kW)
-
Filter
Size (mm)
456×470
Number
1
Indoor unit connection
Mouth size
ID (mm) of return pipe
9.52
Exhaust pipe ID (mm)
9.52
Condensed water drainage pipe OD (mm)
20
Indoor machine size (mm) length * width * height
500×385×1800
Net weight (kg)
73
Electrical parameters
Maximum current FLA (A)
12.3
Recommended opening (A)
16
 
 
 
Outdoor condenser
 
 
 
Model
ATC05N1
Air volume (m3/h)
3000
Number of fans
1
Power (W)
163
Operating temperature range (degree C)
-15℃~45℃
Size (mm) length x * width * height
890×325×752
Unit weight (kg)
40
The test conditions were as follows: indoor dry bulb temperature was 27, wet bulb temperature was 19, and outdoor dry bulb temperature was 35
 
Matters needing attention:
1) the use of UPS environment should pay attention to good ventilation, conducive to heat dissipation, and keep the environment clean.
2) do not bring inductive load, such as currency counter, fluorescent lamp, air conditioning, etc., so as not to cause damage.
3) the output load of UPS is controlled at about 60%, and the reliability is the highest.
4) UPS carrying too light (such as 1000VA UPS band 100VA load) may cause deep discharge of the battery, will reduce the battery life, should be avoided as far as possible.
5) proper discharge will contribute to the activation of the battery, such as the long-term non-stop power supply, every three months should be artificially cut off the city electricity with UPS load discharge once, so as to extend the service life of the battery.
6) for most small UPS, go to work to open UPS, boot to avoid load start, work should be closed UPS; for the network room UPS, because most of the network is 24 hours of work, so UPS must be all-weather operation.
7) UPS discharge should be charged in time to avoid damage to the battery due to excessive self discharge.
 
Warranty service content:
 
1, our store sales products enjoy the factory standard warranty period and warranty service
 
2, the warranty period provided by us free repair or replacement service (shipping by the buyer)
          
3, our shop provides free technical advice and troubleshooting; if you need engineers to install, debug or repair, you need to collect the corresponding travel expenses and installation fees.
 