Menu

Connect with us

KEJIKEYI Hangzhou West DTY-220D10XE half wave type isolated single phase AC voltage regulator module

KEJIKEYI Hangzhou West DTY-220D10XE half wave type full isolation single-phase AC voltage regulating module of the shop and sales of various low-voltage electrical instruments, main CHINT LG Schneider SIEMENS, Shanghai Yatai Wenzhou Wenzhou Dahua Yuyao techtrans temperature control instrument, and details of the consultation seller

price:USD$88.00
discount 70% in 2018-09-21 to 2018-09-23
price: USD$ 61.60
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

KEJIKEYI Hangzhou Xizi solid state relay Co., Ltd.

Model:0-5V control of DTY-220D10XE half wave type voltage regulator module

Other models are required to contact the seller for order

All new products are sold in this shop

Support the original inspection seven days no reason to return

We also sell all kinds of low voltage electrical apparatus and instruments

DTY-220D10XE DTY-220D20XF DTY-220D20XG DTY-220D20XH

The model for the input control signal type, E 0-5V; F said 0-10V; G 4-20mA; H 1-5V.

 

Full isolation single-phase AC voltage regulator module (hereinafter referred to as the single-phase voltage regulating module DTY) is a set of synchronous transformer, phase detection circuit, phase shift trigger circuit and output SCR in one, when changing the control voltage of the size, you can change the output triggering angle, namely single alternating current voltage regulator. According to the common type of a bidirectional thyristor output SCR, two one-way thyristor inverse parallel enhanced and a unidirectional thyristor half wave type three. According to the rated voltage of single-phase AC load is divided into 220V and 380V two, according to the different control signals of E, F, G, H and other four categories, the following specifications: (Note: the current level of SCR module within the maximum current effective value)

List of 2 models

 

type
Electric current
220V load
The optional EFGH
380V load
The optional EFGH
Enhancement type
15A
DTY-H220D15EDTY-H380D15E
35A
DTY-H220D35EDTY-H380D35E
55A
DTY-H220D55EDTY-H380D55E
75A
DTY-H220D75EDTY-H380D75E
120A
DTY-H220D120EDTY-H380D120E
150A
DTY-H220D150EDTY-H380D150E
190A
DTY-H220D190EDTY-H380D190E
240A
DTY-H220D240EDTY-H380D240E
290A
DTY-H220D290EDTY-H380D290E
350A
DTY-H220D350EDTY-H380D350E
Ordinary type
10A
DTY-220D10EDTY-380D10E
25A
DTY-220D25EDTY-380D25E
40A
DTY-220D40EDTY-380D40E
Half wave mode
10A
DTY-220D10XEDTY-380D10XE
25A
DTY-220D25XEDTY-380D25XE
50A
DTY-220D50XEDTY-380D50XE

Note: the type of input control signal type, E 0-5V; F said 0-10V; G 4-20mA; H 1-5V.

 

 E seriesF seriesG seriesH series
Input range0~5V0~10V4~20mA1~5V
Input impedance>30KΩ>30KΩ250Ω>30KΩ
Effective input range0.75~4.75V1.5~9.5V5~19mA1.25~4.75V
Range of phase shift angle150°~0°150°~0°150°~0°150°~0°

 

The output voltage level is 380VAC, which can be used in the power grid less than 420Vac. According to the different thyristor in the module, like the solid state relay, it can also be divided into ordinary, enhanced and half wave type. The half wave type is a one-way thyristor as the output contact, only to the voltage of the positive half cycle regulator (anode module internal unidirectional thyristor with cathode grounding terminal 1, terminal 2).

The third module internal synchronous transformer primary, 220VAC and 380VAC two specifications: 220VAC specifications of the module is allowed to use in the 165 240VAC range of the power grid, the 380VAC specification module allows the use of 285-420VAC in power grid, and the no name end.
The COM is the internal terminal, the CON is the control end, and the +5V terminal is internally generated for manual control of the potentiometer. The weak part of the strong electricity part and the +5V, CON and COM are all isolated.

Half wave modeAirport combination for electric shock
Ordinary typeLow current module or dv/dt requires lower occasions
Enhancement typeHigh current module or dv/dt requires higher occasions
220V220V loop load
380V380V loop load (i.e. two firing lines added to the load)
Current capacity selectionWhen the resistive load is selected, the current rating of the SSR should be more than or equal to 2 times the rated current of the load.
When the load is an AC motor, the current rating of SSR must be greater than or equal to 6-7 times the rated current of the motor.
When the alternating current electromagnet, the intermediate relay line protection, the inductance coil and so on load, selects the SSR current class to be supposed to be more than or equal to 4 times the load rated current.
When the load of power compensation capacitor is selected, the current rating of SSR must be more than 5 times the rated current of the load.
The transformer requires equal to or greater than 5 times the rated current of the transformer primary, special inductive and capacitive load should be based on the current actual experience to enlarge SSR margin.


The single phase AC voltage regulator module can select the following radiators:

 

E-40/F-70/F-100/G-120/G-150/G-185/A-250/A-330

1, such as voltage through the voltage applied on the load and the contents are not the same, please user statement of both voltage, we can custom, but the two phase must be the same, and it must be the voltage level of 220VAC or 380VAC, 50HZ. There was no polarity between the two groups. For example: a load rated voltage is 36VAC (for 220V power grid transformer step-down), selection of 75A single-phase voltage module, can be customized to our model for the TY-H36D75P-220 module, wherein the pin is connected in series with the load to the 36V grid, and the foot is connected to the 220V power grid.

2, CON must be positive for COM, if polarity is opposite, output is out of control (fully open or fully closed). When the control terminal CON changes from 0-5V, the voltage on the AC load is adjustable from 0 volts to the maximum (for resistive load). The CON is about 0-0.75V in the fully closed area, reliable output shutdown module; CON in 0.75V-4.75V for adjustable region, with the increase of the control voltage, conduction angle decreases from 150 DEG to 0 DEG linear, AC voltage on the load from tens of volts increases to a maximum at about 4.75V-5V CON; when the open area, AC voltage on the load is the maximum value.

3. The input impedance of E, F and H series CON is greater than 30K, and the input impedance of G series CON to COM is 250 ohms, COM. +5V voltage signal is only provided for manual potentiometer, not for it, the selected potentiometer resistance is between 2-10K ohms.

4 speed, single-phase AC asynchronous motor frequency converter should normally, only the wind machine, pump motor and other soft load characteristics, or torque motor occasions through the regulator to achieve speed.

5, three single-phase voltage regulator modules can not be used in three-phase power grid for three-phase load voltage regulationThree phase voltage regulation)。

6. The insulation voltage between the weak current part, the strong current part and the module bottom plate is greater than 2000VAC.

7. The heat output of the whole module is calculated by 1.5 watts / ampere according to the actual ampere current of the load, and the radiator can choose E-40, F-70, F-100 and G series

8, the selection of the current level and protection and other related matters needing attention please refer toSingle phase AC solid state relay

9, if the load voltage regulation, high voltage requirements, please increaseVoltage negative feedback module

Selling brand: Schneider CHINT LS OMRON OMRON SIEMENS Matsushita Electric production Taiwan days Otto Nicks amleang matsubishi etc.

Instrument brand: Wenzhou huou Wenzhou through Shanghai Yatai Yuyao techtrans instrument instrument instrument in Yuyao Yuyao Jetta ZHA Zhenhua Yuyao instrument factory of Wenzhou Dahua three meter etc.

Details can consult the seller want, more products, shelves relatively slow

Note: all the goods in this store are free of tax and no transportation

Synchronous sales of solid stores, reasonable price, big price, non standard, contact the shopkeeper to confirm

In order to reduce disputes and misunderstandings, please buy before you confirm whether you buy the goods you are required to buy models, specifications, and voltage. You may need to buy baby, right according to the quantity you need into the shopping cart, please fill out the correct recipient information, address should be detailed, and please keep the phone open, because before delivery, usually with your phone. In addition, please pay attention to each choice of express friends, please confirm whether your regional express can be sent, so as not to delay your use time.

Delivery time

  • Take the payment before 16:00 p.m., and deliver the goods on the same day.
  • If the goods are specially designed, they will be shipped according to the good time of both parties

Delivery logistics

  • This shop defaults to hairRhymeExpress (such as buyers request, we will be sent by buyers express)

Intimate service

  • Customers have special requirements, please contact customer service, and message note, we will send more message content shipped